Mircom TX3 Series User's Guide Page 29

  • Download
  • Add to my manuals
  • Print
  • Page
    / 61
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 28
Configurable Features
Version 2.2 TX3-CX Card Access System Installation and Operation Manual 29 (61)
LT-980 Copyright 2015
Auto-unlock
PIN required schedule
Access levels
2.6 Holidays
Up to 128 holidays can be entered in the system. Each holiday consists of the
following:
start time/date
end time/date
If a holiday falls on the same date each year it can also be programmed as an
annual event.
Each holiday has a holiday ID and label to identify the holiday for use in the
configurator software.
By default, New Year (January 1) is already programmed into the system.
2.7 System Status
The controller monitors inputs for trouble and alarm conditions.
2.7.1 Common trouble
The common trouble indicator is active when any of the following inputs receive
a trouble condition:
Any supervised input
Power (AC and battery)
Door held open warning
The common trouble status clears only if all the above inputs are back in normal
state. When the common trouble status is active, the common trouble led flashes
at a slow rate.
2.7.2 Common alarm
The common alarm status is active when any of the following inputs receive an
alarm condition:
forced entry alarm
Page view 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 60 61

Comments to this Manuals

No comments