Configurable Features
Version 2.2 TX3-CX Card Access System Installation and Operation Manual 25 (61)
LT-980 Copyright 2015
Auto relock. Enabling this option locks the door when the door closes before the
door open timer or extended door timer expires. Disabling this option locks the
door, but only after the expiration of door open timer or extended door open
timer.
Deduct usage count. For cards designated as “temporary” (that is, the usage
counter option is enabled and set to a value below 255), this option decreases the
usage counter by one every time this card is used at the access point. When the
usage counter reaches zero, the card deactivates.
Disable forced entry alarm. Disabling the forced entry alarm will not activate
the forced entry alarm even if the door is opened without permission. Instead an
access granted sequence is started. This is usually used on access points where
there is no request to exit (RTE) device.
Ignore card facility code. This option is enabled by default meaning that only
card number will be processed. If this option is unchecked, then for every card,
card number and facility code will be processed to grant access.
PC decision required. When enabled granting access is transferred to the PC
from the controller. For this option to work the PC needs to be on all the time with
an attendant. Use this option when the building has a security desk or a concierge.
First person In. Configuring the access point for the lock/unlock schedule,
causes the door to remain locked at the start of the unlock schedule, until the first
valid card with this privilege is presented to the card reader. The door continues
to remain unlocked for the remainder of the unlock schedule.
RTE bypass DC. When enabled, requests to exit (RTE) bypass the door contact
(DC) and do not unlock the door. This is typically used where there is a
mechanical egress device installed on the door.
High security. When enabled only access cards with the high security privilege
are able to open the door.
Report request to exit. This option logs and monitors events and system status.
When enabled any requests to exit are logged and reported to the configurator.
Since the person exiting is not known, only the time and date and the request itself
is logged and reported.
Report door not opened. When enabled this option logs and reports events
when access is granted but the door remains closed.
Report unknown format. When enabled this option logs and reports access
attempts with a card with an unknown format.
Facility code mode. Enabling this mode grants access to cards based on only
their facility code. This allows nonprogrammed cards to have complete building
access. Use only when necessary.